Firefighters' portable radios may fail at high temperatures

Wednesday, 17 December, 2014

New test results from the US National Institute of Standards and Technology (NIST) confirm that portable radios used by firefighters can fail to operate properly within 15 minutes when exposed to temperatures that may be encountered during firefighting activities.

Performance problems with portable radios have been identified by the National Institute for Occupational Safety and Health as contributing factors in some firefighter fatalities.

All seven of the firefighter portable radios tested by NIST failed to perform properly within 15 minutes when exposed to temperature levels encountered in ‘fully involved’ fires, as when all the contents in a room or structure are burning.

Four of the handheld radios stopped transmitting, and three experienced significant ‘signal drift,’ rendering them unreliable for communication.

The failures occurred while the radios were subjected to a temperature of 160°C, termed Thermal Class II conditions (see NIST Technical Note 1474 at http://fire.nist.gov/bfrlpubs/fire06/PDF/f06001.pdf).

The temperature is representative of a fully involved fire or conditions outside a room when its contents burst into flames simultaneously, a phenomenon known as flashover.

During the post-test cool-down period, three of the radios did not recover normal function.

Portable radio in a test rig

A portable firefighter radio is instrumented for testing in a NIST-designed apparatus that consistently creates thermal conditions representative of typical fire environments. Credit: NIST

Funded by the US Department of Homeland Security, the NIST tests further ongoing work to develop performance standards for firefighter portable radio equipment, which includes radios, wearable combinations of speakers and microphones, and related items.

The existing standard provides only general guidance - that portable radios “be manufactured for the environment in which they are to be used”.

NIST researchers are furnishing their test data and performance measurements to the US National Fire Protection Association, which is developing a performance standard for portable radios used by emergency personnel.

As important, the NIST team designed a prototype apparatus to electronically control testing equipment intended to consistently create thermal conditions representative of typical fire environments.

All radios tested by NIST performed reliably when exposed to a temperature of 100°C for 25 min, or Thermal Class I conditions, akin to a small fire in a room or fighting a fire from a distance.

No tests were conducted under more extreme fire conditions (Thermal Classes III and IV).

“Realistic and reliable performance tests provide clear design targets for portable radio manufacturers,” explained NIST fire protection engineer Michelle Donnelly. “Standards incorporating these tests provide firefighters with the assurance that their equipment will perform as expected under specified thermal conditions.”

For more information, see MK Donnelly, WF Young, and D Camell, Performance of Portable Radios Exposed to Elevated Temperatures (NIST Technical Note 1850); September 2014.

Related News

Govt funds mobile coverage boost for regional Vic, NSW

The Australian Government is improving mobile coverage on our regional roads and highways with...

Optus fined $12m for Triple Zero outage

The ACMA found Optus failed to provide access to the emergency call service for 2145 people...

Cognitive monitoring network service to improve mine safety

The cognitive monitoring network service enables performance, reliability and safety enhancements...


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd